Calculator Notes: Half-Lives of Signals and Messengers
Every loop has an off switch. A phosphorylated receptor is dephosphorylated, a ligand is degraded, a transcription factor leaves the nucleus. When those steps follow simple first-order kinetics, their speed can be summarised by a half-life. This page shows how to convert between rate constants and half-lives, how to predict what fraction of a signal is left after a chosen time, and where the arithmetic stops matching real cells.
Three formulas worth memorising
| Quantity | Expression | Use it to |
|---|---|---|
| Half-life | t1/2 = ln 2 / k ≈ 0.693 / k | Convert a rate constant into a time you can picture |
| Fraction remaining | f = e−kt = (1/2)t / t1/2 | Predict how much active signal is left after time t |
| Mean lifetime | τ = 1 / k ≈ 1.44 × t1/2 | Estimate the average time one molecule stays active |
Keep units consistent. If k is per minute, the half-life comes out in minutes.
Worked example: a phospho-signal after stimulation stops
Illustrative scenario. Lab A stimulates cells with a growth factor, then washes the factor out and adds a receptor kinase inhibitor so no new phosphorylation occurs. Suppose the phosphorylated form of a downstream kinase decays with k = 0.07 per minute.
- Half-life: 0.693 / 0.07 ≈ 10 minutes.
- After 30 minutes, three half-lives have passed, so (1/2)3 = one-eighth of the starting signal remains.
- After one hour, six half-lives: about one sixty-fourth, close to background on most blots.
Now compare a hypothetical secreted ligand in culture medium with a half-life of 8 hours. Over a 24-hour experiment it loses only seven-eighths of each batch released, so conditioned medium keeps accumulating active ligand. The contrast explains a common pattern: intracellular phospho-signals are reset within minutes, while extracellular messengers can build up over hours and keep a loop running.
How feedback distorts the simple curve
Real decay curves are often not single exponentials, and the shape carries information:
- Faster-than-expected drop. If signalling itself induces a phosphatase, such as the dual-specificity phosphatases that dephosphorylate ERK, removal speeds up over time. The curve steepens after a delay.
- A shoulder or plateau. A residual positive loop, for example an autocrine ligand still present in the dish, keeps re-phosphorylating the target and slows the apparent decay.
- Two phases. A fast component and a slow tail can mean two pools, such as surface and internalised receptors, each turning over at its own rate.
A useful check is to plot the logarithm of the signal against time. A single first-order process gives a straight line whose slope is −k. Curvature tells you the process is not that simple.
Limits
Half-life arithmetic assumes a constant rate and no ongoing production. Western blot band intensities are only semi-quantitative, so treat values derived from them as rough. For background on termination mechanisms see the page on phosphatases in signal termination, and look up unfamiliar terms in the glossary.