A Checklist Before Running a Growth Factor Stimulation Assay
Stimulating cultured cells with a growth factor and measuring phosphorylated proteins is one of the most common experiments in signalling labs, and a frequent component of autocrine-loop studies. It is also easy to get wrong in ways that make results uninterpretable. This checklist lists the decisions to make before you start, each with a one-line reason. It is written for supervised teaching and research labs and assumes local safety training is in place.
Preparing the cells
- Record passage number and confluence. Signalling responses change with density and with long-term culture.
- Decide on serum reduction. Lowering serum beforehand reduces background activation from serum factors, but long starvation can stress cells; follow your lab's protocol for the cell type.
- Consider the cells' own secretions. If an autocrine loop is suspected, medium conditioned during starvation already contains ligand; a fresh-medium change before stimulation helps define baseline.
- Plate replicate wells at the same time. Wells seeded on different days are not comparable.
Designing the stimulation
- Choose a dose range, not a single dose. A range reveals sensitivity; a saturating dose only shows capacity.
- Include a vehicle control. Growth factors are diluted in carrier solutions that should be added alone to control wells.
- Plan time points that capture rise and fall. Early points within minutes and later points over hours are typical for receptor and ERK phosphorylation; the exact set depends on the question.
- Add an inhibitor arm if testing dependence. A receptor kinase inhibitor or blocking antibody shows which receptor drives the signal.
- Stagger additions so every well is lysed on time. A few minutes' delay matters for fast signals.
Lysis and readout
- Use phosphatase and protease inhibitors in the lysis buffer. Phosphorylation is lost quickly once cells are broken open.
- Keep samples cold and process them consistently. Differences in handling create differences in signal.
- Measure total protein and load equally. Band intensity comparisons depend on it.
- Probe for both phospho and total forms. This separates changes in activation from changes in amount.
- Include a loading control. A housekeeping protein or total-protein stain confirms equal loading.
Analysis
| Check | Reason |
|---|---|
| Biological replicates on separate days | Shows the result is reproducible, not a one-off |
| Quantify within the linear range of detection | Saturated bands cannot be compared |
| Report phospho / total ratio | Normalises for protein amount |
| Show uncropped blots in supplementary material | Lets readers check specificity |
Use the feedback experiment worksheet to structure the question, the time course diagnostic to interpret the shape, and the phospho-blot figure guide when presenting results.
One further point is easy to overlook: write the plan down and share it before the day of the experiment. A supervisor or colleague can spot a missing control in minutes, whereas discovering it after lysis means repeating the whole run. The lab notebook template has fields for each item on this checklist. It is also worth running a small pilot with one dose and two time points before a full experiment, to confirm that the antibodies detect the expected bands and that the stimulus produces a visible change.