Quick Tips on Ligand Concentrations: Mass, Molar and Back Again

Papers on signalling loops report ligand concentrations in different units. Protein suppliers usually quote mass per volume, such as nanograms per millilitre, while binding studies use molar units, such as nanomolar or picomolar. Comparing a dose with a receptor's affinity needs both. These tips make the conversion routine, each with a one-line reason.

The conversion itself

Molar concentration equals mass concentration divided by molecular mass. The key is to keep units consistent. A practical shortcut: a concentration in nanograms per millilitre, divided by the molecular mass in kilodaltons, gives the concentration in nanomolar. That works because nanograms per millilitre equals micrograms per litre, and a kilodalton protein weighs a thousand grams per mole.

Illustrative ligand massIllustrative doseApproximate molar concentration
6 kDa10 ng/mLAbout 1.7 nM
15 kDa10 ng/mLAbout 0.67 nM, or 670 pM
25 kDa1 ng/mLAbout 40 pM

The masses in the table are round illustrative numbers, not the values for particular proteins. Always use the molecular mass stated by the supplier for the exact form you are using.

Tips

  1. Check which mass the supplier means. Some quote the monomer, others the active dimer or trimer. Why: it can change the molar result by a factor of two or three.
  2. Note glycosylation. Proteins made in mammalian cells may be heavier than the sequence predicts. Why: the real molecular mass may differ from the calculated one.
  3. Convert before comparing with affinity. A dissociation constant is in molar units. Why: comparing ng/mL with nM directly is meaningless.
  4. Remember the factor of a thousand. 1 nM equals 1000 pM. Why: slipping a factor of a thousand is the commonest error.
  5. Write the conversion in your notebook. Why: it lets you and others check the arithmetic later.
  6. Think about molecules per cell too. The total amount of ligand in a well, compared with the number of receptors on the cells, tells you whether ligand might be depleted. Why: in small volumes cells can consume a large share of the ligand.
  7. Use activity units with care. Some cytokines are sold by activity units from a bioassay. Why: units are not interchangeable between suppliers.
  8. Record the carrier protein. Many ligands are supplied with albumin as a carrier. Why: carrier can affect how much free ligand is available.

Why this matters for autocrine loops

Autocrine experiments often compare the effect of added ligand with the effect of the cell's own secreted ligand. To judge whether the cells could plausibly make enough of their own factor, you need to put both in the same units and compare them with the receptor's affinity. A concentration measured in conditioned medium at tens of picomolar may be enough to occupy high-affinity receptors, while the same number may be negligible for a low-affinity receptor. Doing the conversion turns a list of doses into an argument about whether the loop can work.